CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE
After that it will prompt the user to enter the data. The display as following: -
Digits in the ( ) bracket are under focus.
This is the start of the Expiry Date setting. The earliest Start Date is 01/01/1998.
After keying the Start Date, the display will be changed as following: -
Digits in the ( ) bracket are under focus.
This is the end of the Expiry Date setting. The latest End Date is 31/12/2030.
After keying the End Date, the display will be changed as following: -
00-255 is available. This option lets user to set the TimeZone for the card user. The
card user only can access the door within the TimeZone.
Repeat the step to proceed to Door_02_TZ (2s), Door_04_TZ (4s) or Door_08_TZ (8s).
Access Level Door 1 (Tz) Door 2 (Tz) Door 3 (Tz) Door 4 (Tz)
Default 000 000 000 000 000
Default 001 001 001 001 001
002 001 002 000 000
003 002 000 000 000
004 003 003 003 003
Parameters
Press ‘8’ key to select [8.Param] menu from the System Menu.
This menu item sets the controller System Parameter. When user select this menu, the
controller will step through each of the System Parameters.
The System Parameters are listed as below: -
a. Card Lock-Out Mode
‘ON’ / ‘OFF’ value. When this option is set, the card user will only be allowed 3
invalid access attempts (Card & Pin Mode and Anti-Passback) after the user will be
locked out from the system. Access will need to be manually granted. User cards
that have been locked out can only be used again after resetting the Lock Out Flag.
This is described in the DBASE Menu.
CASS TECHNOLOGY SDN BHD(338857-X) 24
dd/mm DDD hh:mm:ss
St (00) / [00] / [0000]
dd/mm DDD hh:mm:ss
Ed (00) / [00] / [0000]
dd/mm DDD hh:mm:ss
Door 01 Tz (000 )