Cass Technology CASTLE S SERIES Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Bezpečnostní systémy pro řízení přístupu Cass Technology CASTLE S SERIES. S-Series - Door Controller (Commando) Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - OPERATION GUIDE

TECHNICAL OPERATION GUIDECASTLE COMMANDO SERIES CONTROLLER CASS TECHNOLOGY SDN BHD(338857-X)

Strany 2 - CASS TECHNOLOGY SDN BHD

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE

Strany 3 - Contents Page

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE (This menu not available in C16v1-20 and above)

Strany 4 - ARD READER LED INDICATORS

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Key Functions in Programming ModeThe '0' to '9' keys are used for en

Strany 5 - Chapter 1 -COMPONENTS

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE After keying the password, the Main Programming Menu will be shown on the LCD.Use the ‘A

Strany 6

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 4 – System MenuCASS TECHNOLOGY SDN BHD(338857-X) 141.System1.Date and Time2.Door

Strany 7 - Access Granting

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Under the System Menu, the user can change the Date and Time, Do

Strany 8 - Special Purpose Time Zone

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Digits in the ( ) bracket are under focus.Proceed in the same way to change

Strany 9 - Programming Menu Structure

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE d. Out Location CodeA value of 00-99 is allowed. This value determines the door Out Loca

Strany 10

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE g. Card + PIN TimeZoneA value of 00-255 is allowed. This item is used to set the reader

Strany 11

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE j. Local PIN 14 digits of number are required to set the Local Auto-PIN number. This is

Strany 12 - Password [ ]

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Disclaimer ©2004 Cass Technology Sdn Bhd, All Right Reserved. Information of this docume

Strany 13

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE o. PIN Mode‘ON/OFF’ value. When the PIN Mode is set to ON, the user has to key in the Au

Strany 14 - Chapter 4 – System Menu

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Setting TimerSetTimeSet is the time period setting activation of an operation.In cardhol

Strany 15

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Press ‘4’ key to select [4-Timers] menu from the system menu.This menu item sets the Tim

Strany 16

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE a. Manager/director with TimeZone #001,b. Normal staff with TimeZone #002 andc. Cleaners

Strany 17

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE After that it will prompt the user to enter the data. The display as following: -Digits

Strany 18

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE b. Check Expiry‘ON’ / ‘OFF’ value. When this option is set, the system will check the Ex

Strany 19

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 5 – Database Menu

Strany 20

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Installing CardPress ‘1’ key to select [1-Install] menu from Database Menu.This menu i

Strany 21 - Setting TimerSet

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE View Card DatabasePress ‘3’ key to select [3-View DB] menu from Database Menu.This menu

Strany 22 - Setting Time Zone

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE View Log TransactionPress ‘4’ to select [4-View Lg] menu from Database Menu.This menu it

Strany 23

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Contents PageCHAPTER 1 – COMPONENTSSYSTEM CONFIGURATION5CHAPTER 2 - OPERATION OVERVIEWAC

Strany 24

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Reset Anti-Passback FlagPress ‘6’ key to select [6-Rst A/p] menu from Database Menu.This

Strany 25

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 6 – General Purpose OutputUnder General Purpose Output Menu, user can manually s

Strany 26 - Chapter 5 – Database Menu

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 7 – Event OutputUnder Event Output Menu, user can manually program any 20 types

Strany 27

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE 20 types of transaction code are allowed. These transaction code is

Strany 28 - 123456 ALVL001

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 8 – SensorUnder Sensor menu, user can manually arm the sensor and set the TimeZo

Strany 29 - Clear Card (Y=ENT) ?

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Alarm Delay Time Value 00 to 255 is allowed. The value indicates the time in seconds. Th

Strany 30

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 9 – Maintenance MenuUnder Maintenance Menu, user can change the Pro

Strany 31 - 0.Return to Main

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Changing PasswordPress ‘1’ to select [1-CH Pass] menu from the Maintenance Menu.This me

Strany 32 - Chapter 7 – Event Output

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Test KeypadPress ‘1’ to select [1-Tst Kpd] menu from the Test Menu.Then the controller w

Strany 33 - Return to Main Menu

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Readers StatusPress ‘5’ select [5-Rd Stat] menu from the Test Menu.Then the controller w

Strany 34 - Chapter 8 – Sensor

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE CHAPTER 9 – MAINTENANCE MENU Change Password Set String Test Keypad Test Watchdog

Strany 35

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 10 – InformationPress ‘7’ to select [7-Info] from the Main Menu.Then the control

Strany 36 - Chapter 9 – Maintenance Menu

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 11 – CASTLE-S ReaderProgramming During Emergency Mode At The ReaderWhen the

Strany 37

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Change Card PIN NumberUsing the Reader, user can change his/her Access C

Strany 38

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 12 – Wiring Diagrami. CTA 16 – Door Access Control Board Layoutii. CTA 16 – Comm

Strany 39

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE iii. CAS 12s – 12 Door Access Control Board Layoutiv. CAS 12s – Commando and Reader Inte

Strany 40 - Chapter 10 – Information

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 1 -COMPONENTS System ConfigurationBelow are the basic system configurations of t

Strany 41 - Chapter 11 – CASTLE-S Reader

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE d. Door SensorThe door sensor is use for detecting whether the door is closed or opene

Strany 42

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 2 - Operation OverviewAccess CardEach user of the Castle Commando Card Acces

Strany 43 - Chapter 12 – Wiring Diagram

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Special Purpose Time ZoneCASTLE-Commando has special TimeZone, namely:a. Door #1 to Door

Strany 44

CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE Chapter 3 - Programming The CommandoThis section is explaining the CASTLE-Comm

Komentáře k této Příručce

Žádné komentáře